Gas Engine Generator100kVA Cummins Gas Engine Generator SetGas Engine Generator SetGenerator

100kva Gas Generator Set 

 

1. Main Specifications

Model

HTG-80GFS

 

Rated current

144A

Rated power

80kW/100kVA

Power factor

0.8

Standby power

88kW/110kVA

Controller

Auto PLC controller Smartgen HGM6110

Rated voltage

400V/230V

Speed Governor

Electric control

Rated frequency

50Hz

Fuel

Natural Gas

Rated speed

1500 rpm

Gas Consumption

0.3m³/kW·h

* Sea-Level<1000m, Temp<40.

* Prime Power (PRP): Prime power is available for an unlimited number of annual hours in variable load application, in accordance with GB/T2820-97 (eqv ISO8528); A 10% overload capability is available for a period of 1 hour within a 12-hour period of operation.

* Standby Power Rating (ESP): The standby power rating is applicable for supplying emergency power for the duration of a utility power interruption. No overload, utility parallel or negotiated outage operation capability is available at this rating.

* Rated Voltage: generally the rated power includes 380/220V, 400/230V, 415/240V, 440/254V, we make it according to client's requirements.

 

2. Engine Technical Parameters

Engine Model

CumminsTECH /HT6BTAA5.9-NG

Rated Power

90kW

Engine Type

In-line, Four Stroke, Electronic Ignition

Rated Speed

1500 rpm

Cylinder No.

6 in line

Bore ×Stroke

102×120mm

Displacement

5.9 L

Start Method

Electric

Compression Ratio

11.9:1

Crankshaft Rotation Direction

Inverse Hour (From Flywheel)

Cooling Method

Closed Water Cooling

Aspiration Type

Turbocharge

Speed Governor

Electronic

Gas Mixer Formation

Pre-Mix

Rated Fue Consumption (m³/kW·h)

0.3

 

3. Alternator Technical Parameters

Alternator Model

Leroy Somer/TAL-A44-D

Insulation class

Class H

Rated Power

80kW/100kVA

Connection

3-pahse, 4-wire

Standby power

88kW/110kVA

Cooling

Air cooled

Power factor

0.8

Protection Class

IP23

Excitation Type

Brushless

Voltage Regulation Mode

AVR (Automatic)

 

4 Electrical performance

Voltage setting range

≥±5%

Steady - state frequency regulation

≤1%

Steady-state voltage regulation

≤±1%

Frequency fluctuation rate

≤1.5%

Transient voltage deviation (100% Sudden power reduction)

≤+25%

Transient frequency deviation (100% Sudden power reduction) 

≤+12%

Transient voltage deviation (Sudden power plus)

≤-20%

Transient frequency deviation(Sudden power plus)

≤-10%

Voltage stabilization time (100%Sudden power reduction)

≤6S

Frequency recovery time (100%Sudden power reduction)

≤5S

Voltage stabilization time (Sudden power plus)

≤6S

Frequency recovery time(Sudden power plus)

≤5S

 

Gas Engine Generator


Please E-mail us for more details by sun@sves.cn



Get the latest price? We'll respond as soon as possible(within 12 hours)
This field is required
This field is required
Required and valid email address
This field is required
This field is required
For a better browsing experience, we recommend that you use Chrome, Firefox, Safari and Edge browsers.