Gas Engine Generator100kVA Cummins Gas Engine Generator SetGas Engine Generator SetGenerator
100kva Gas Generator Set
1. Main Specifications | ||||
Model | HTG-80GFS |
| Rated current | 144A |
Rated power | 80kW/100kVA | Power factor | 0.8 | |
Standby power | 88kW/110kVA | Controller | Auto PLC controller Smartgen HGM6110 | |
Rated voltage | 400V/230V | Speed Governor | Electric control | |
Rated frequency | 50Hz | Fuel | Natural Gas | |
Rated speed | 1500 rpm | Gas Consumption | 0.3m³/kW·h | |
* Sea-Level<1000m, Temp<40℃. * Prime Power (PRP): Prime power is available for an unlimited number of annual hours in variable load application, in accordance with GB/T2820-97 (eqv ISO8528); A 10% overload capability is available for a period of 1 hour within a 12-hour period of operation. * Standby Power Rating (ESP): The standby power rating is applicable for supplying emergency power for the duration of a utility power interruption. No overload, utility parallel or negotiated outage operation capability is available at this rating. * Rated Voltage: generally the rated power includes 380/220V, 400/230V, 415/240V, 440/254V, we make it according to client's requirements. |
2. Engine Technical Parameters | |
Engine Model | CumminsTECH /HT6BTAA5.9-NG |
Rated Power | 90kW |
Engine Type | In-line, Four Stroke, Electronic Ignition |
Rated Speed | 1500 rpm |
Cylinder No. | 6 in line |
Bore ×Stroke | 102×120mm |
Displacement | 5.9 L |
Start Method | Electric |
Compression Ratio | 11.9:1 |
Crankshaft Rotation Direction | Inverse Hour (From Flywheel) |
Cooling Method | Closed Water Cooling |
Aspiration Type | Turbocharge |
Speed Governor | Electronic |
Gas Mixer Formation | Pre-Mix |
Rated Fue Consumption (m³/kW·h) | 0.3 |
3. Alternator Technical Parameters | |||
Alternator Model | Leroy Somer/TAL-A44-D | Insulation class | Class H |
Rated Power | 80kW/100kVA | Connection | 3-pahse, 4-wire |
Standby power | 88kW/110kVA | Cooling | Air cooled |
Power factor | 0.8 | Protection Class | IP23 |
Excitation Type | Brushless | Voltage Regulation Mode | AVR (Automatic) |
4 Electrical performance | |||
Voltage setting range: | ≥±5% | Steady - state frequency regulation | ≤1% |
Steady-state voltage regulation: | ≤±1% | Frequency fluctuation rate | ≤1.5% |
Transient voltage deviation (100% Sudden power reduction) | ≤+25% | Transient frequency deviation (100% Sudden power reduction) | ≤+12% |
Transient voltage deviation (Sudden power plus) | ≤-20% | Transient frequency deviation(Sudden power plus) | ≤-10% |
Voltage stabilization time (100%Sudden power reduction) | ≤6S | Frequency recovery time (100%Sudden power reduction) | ≤5S |
Voltage stabilization time (Sudden power plus) | ≤6S | Frequency recovery time(Sudden power plus) | ≤5S |